Article 1 
Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as set out in the Annex to this Regulation.
Article 2 
This Regulation shall enter into force on the first day following its publication in the Official Journal of the European Union.
It shall apply from 13 April 2010.
This Regulation shall be binding in its entirety and directly applicable in all Member States.Done at Brussels, 21 April 2010.
For the Commission
The President
José Manuel BARROSO
ANNEX

Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:

1.. Annex I is amended as follows:

((a)) the title is replaced by the following:
'';
((b)) the introductory sentence in point 1 is replaced by the following:
'The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:';
((c)) points 1(c) and 1(d) are replaced by the following:
'
((c)) blended high intensity discharge lamps having:

— 6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and
— 11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and
— 5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;
((d)) blended high intensity discharge lamps having:

— the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);';
((d)) point 2 is replaced by the following:
'
2. 

((a)) products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;
((b)) lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council or Directive 1999/92/EC of the European Parliament and of the Council;
((c)) emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council.
((d)) ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;
((e)) luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the Council, Council Directive 93/42/EEC, Council Directive 88/378/EEC and luminaires integrated into equipment covered by these requirements.

The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.
'
2.. Annex II is amended as follows:

((a)) the first sentence is deleted;
((b)) The following sentence is added to point 1(c):
‘For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.’
((c)) The following point (o) is added to point 3:
'
((o)) “Blended lamp” means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.'
3.. Annex III is amended as follows:

((a)) The following paragraph is added before Table 1:
'Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.'
((b)) Table 2 is replaced by the following:
'
Small single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin) Double parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin) Triple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin)
Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value
5 48 10 60 13 62
7 57 13 69 18 67
9 67 18 67 26 66
11 76 26 66 
4 legs in one plane, lamp cap 2G10(4 pin) Long single parallel tube, lamp cap 2G11(4 pin) 
Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value 
18 61 18 67 
24 71 24 75
36 78 34 82
 36 81'
((c)) Table 3 is replaced by the following:
'
Triple parallel tubes, lamp cap GX24q(4 pin) Four parallel tubes, lamp cap GX24q(4 pin) Long single parallel tube, lamp cap 2G11(4 pin)
Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value Nominal wattage(W) Rated luminous efficacy (lm/W), 100 h initial value
32 75 57 75 40 83
42 74 70 74 55 82
57 75  80 75
70 74 '
((d)) Table 6 is replaced by the following:
'
Lamp parameter Deduction from luminous efficacy at 25 °C
Tc ≥ 5 000 K -10 %
95 ≥ Ra > 90 -20 %
Ra > 95 -30 %
Second lamp envelope -10 %
Lamp Survival Factor ≥ 0,50 after 40 000 burning hours -5 %'
((e)) In Annex III.1.1.B, the sentence
‘The corrections defined for the first stage (Table 6) shall continue to apply’
is replaced by
‘The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.’;
((f)) The title of Table 7 is replaced by the following:
'';
((g)) The title of Table 8 is replaced by the following:
''
((h)) The second paragraph of Annex III.1.1.C is replaced by the following:
'Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.'
((i)) Table 11 is replaced by the following:
'
Lamp lumen maintenance factor Burning hours
Lamp types 2 000 4 000 8 000 16 000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts 0,95 0,92 0,9 —
T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart 0,96 0,92 0,91 0,9
Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart 0,95 0,92 0,9 0,9
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) 0,8 0,74 — —
0,72 at 5 000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts 0,85 0,83 0,8 —
0,75 at 12 000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts 0,85 0,78 0,75 —
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart 0,9 0,84 0,81 0,78'
((j)) The following introductory phrase and Table 11a is added after Table 11:
'The following cumulative deductions shall be applied to the values in Table 11:
Lamp parameter Deduction from lamp lumen maintenance requirement
Lamps with 95 ≥ Ra > 90 At burning hours ≤ 8 000 h: – 5 %At burning hours > 8 000 h: – 10 %
Lamps with Ra > 95 At burning hours ≤ 4 000 h: – 10 %At burning hours > 4 000 h: – 15 %
Lamps with a colour temperature ≥ 5 000 K -10 %'
((k)) Table 12 is replaced by the following:
'
Lamp survival factor Burning hours
Lamp types 2 000 4 000 8 000 16 000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts 0,99 0,97 0,9 —
Double-Capped Fluorescent lamps on high frequency ballast with warmstart 0,99 0,97 0,92 0,9
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) 0,98 0,77 — —
0,50 at 5 000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts 0,99 0,97 0,85 —
0,50 at 12 000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts 0,98 0,9 0,5 —
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart 0,99 0,98 0,88 —'
((l)) Table 13 is replaced by the following:
'
High pressure sodium lamp category and burning hours for measurement Lamp lumen maintenance factor Lamp survival factor
P ≤ 75 WLLMF and LSF measured at 12 000 burning hours Ra ≤ 60 > 0,80 > 0,90
Ra > 60 > 0,75 > 0,75
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast > 0,75 > 0,80
P > 75 WLLMF and LSF measured at 16 000 burning hours Ra ≤ 60 > 0,85 > 0,90
Ra > 60 > 0,70 > 0,65
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast > 0,75 > 0,55The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.';
((m)) Annex III.1.3(i) is replaced by the following:
'
((i)) Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.';
((n)) The following point (j) is added to point 1.3 of Annex III:
'
((j)) For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.';
((o)) Table 17 is replaced by the following:
'
LAMP DATA BALLAST EFFICIENCY (Plamp/Pinput)
Non-dimmable
Lamp type Nominal Wattage ILCOS CODE Rated/typical wattage A2 BAT A2 A3 B1 B2
50 Hz HF
W W W     
T8 15 FD-15-E-G13-26/450 15 13,5 87,8 % 84,4 % 75,0 % 67,9 % 62,0 %
T8 18 FD-18-E-G13-26/600 18 16 87,7 % 84,2 % 76,2 % 71,3 % 65,8 %
T8 30 FD-30-E-G13-26/900 30 24 82,1 % 77,4 % 72,7 % 79,2 % 75,0 %
T8 36 FD-36-E-G13-26/1200 36 32 91,4 % 88,9 % 84,2 % 83,4 % 79,5 %
T8 38 FD-38-E-G13-26/1050 38,5 32 87,7 % 84,2 % 80,0 % 84,1 % 80,4 %
T8 58 FD-58-E-G13-26/1500 58 50 93,0 % 90,9 % 84,7 % 86,1 % 82,2 %
T8 70 FD-70-E-G13-26/1800 69,5 60 90,9 % 88,2 % 83,3 % 86,3 % 83,1 %
TC-L 18 FSD-18-E-2G11 18 16 87,7 % 84,2 % 76,2 % 71,3 % 65,8 %
TC-L 24 FSD-24-E-2G11 24 22 90,7 % 88,0 % 81,5 % 76,0 % 71,3 %
TC-L 36 FSD-36-E-2G11 36 32 91,4 % 88,9 % 84,2 % 83,4 % 79,5 %
TCF 18 FSS-18-E-2G10 18 16 87,7 % 84,2 % 76,2 % 71,3 % 65,8 %
TCF 24 FSS-24-E-2G10 24 22 90,7 % 88,0 % 81,5 % 76,0 % 71,3 %
TCF 36 FSS-36-E-2G10 36 32 91,4 % 88,9 % 84,2 % 83,4 % 79,5 %
TC-D / DE 10 FSQ-10-E-G24q=1FSQ-10-I-G24d=1 10 9,5 89,4 % 86,4 % 73,1 % 67,9 % 59,4 %
TC-D / DE 13 FSQ-13-E-G24q=1FSQ-13-I-G24d=1 13 12,5 91,7 % 89,3 % 78,1 % 72,6 % 65,0 %
TC-D / DE 18 FSQ-18-E-G24q=2FSQ-18-I-G24d=2 18 16,5 89,8 % 86,8 % 78,6 % 71,3 % 65,8 %
TC-D / DE 26 FSQ-26-E-G24q=3FSQ-26-I-G24d=3 26 24 91,4 % 88,9 % 82,8 % 77,2 % 72,6 %
TC-T / TE 13 FSM-13-E-GX24q=1FSM-13-I-GX24d=1 13 12,5 91,7 % 89,3 % 78,1 % 72,6 % 65,0 %
TC-T / TE 18 FSM-18-E-GX24q=2FSM-18-I-GX24d=2 18 16,5 89,8 % 86,8 % 78,6 % 71,3 % 65,8 %
TC-T / TC-TE 26 FSM-26-E-GX24q=3FSM-26-I-GX24d=3 26,5 24 91,4 % 88,9 % 82,8 % 77,5 % 73,0 %
TC-DD / DDE 10 FSS-10-E-GR10qFSS-10-L/P/H-GR10q 10,5 9,5 86,4 % 82,6 % 70,4 % 68,8 % 60,5 %
TC-DD / DDE 16 FSS-16-E-GR10qFSS-16-I-GR8FSS-16-L/P/H-GR10q 16 15 87,0 % 83,3 % 75,0 % 72,4 % 66,1 %
TC-DD / DDE 21 FSS-21-E-GR10qFSS-21-L/P/H-GR10q 21 19,5 89,7 % 86,7 % 78,0 % 73,9 % 68,8 %
TC-DD / DDE 28 FSS-28-E-GR10qFSS-28-I-GR8FSS-28-L/P/H-GR10q 28 24,5 89,1 % 86,0 % 80,3 % 78,2 % 73,9 %
TC-DD / DDE 38 FSS-38-E-GR10qFSS-38-L/P/H-GR10q 38,5 34,5 92,0 % 89,6 % 85,2 % 84,1 % 80,4 %
TC 5 FSD-5-I-G23FSD-5-E-2G7 5,4 5 72,7 % 66,7 % 58,8 % 49,3 % 41,4 %
TC 7 FSD-7-I-G23FSD-7-E-2G7 7,1 6,5 77,6 % 72,2 % 65,0 % 55,7 % 47,8 %
TC 9 FSD-9-I-G23FSD-9-E-2G7 8,7 8 78,0 % 72,7 % 66,7 % 60,3 % 52,6 %
TC 11 FSD-11-I-G23FSD-11-E-2G7 11,8 11 83,0 % 78,6 % 73,3 % 66,7 % 59,6 %
T5 4 FD-4-E-G5-16/150 4,5 3,6 64,9 % 58,1 % 50,0 % 45,0 % 37,2 %
T5 6 FD-6-E-G5-16/225 6 5,4 71,3 % 65,1 % 58,1 % 51,8 % 43,8 %
T5 8 FD-8-E-G5-16/300 7,1 7,5 69,9 % 63,6 % 58,6 % 48,9 % 42,7 %
T5 13 FD-13-E-G5-16/525 13 12,8 84,2 % 80,0 % 75,3 % 72,6 % 65,0 %
T9-C 22 FSC-22-E-G10q-29/200 22 19 89,4 % 86,4 % 79,2 % 74,6 % 69,7 %
T9-C 32 FSC-32-E-G10q-29/300 32 30 88,9 % 85,7 % 81,1 % 80,0 % 76,0 %
T9-C 40 FSC-40-E-G10q-29/400 40 32 89,5 % 86,5 % 82,1 % 82,6 % 79,2 %
T2 6 FDH-6-L/P-W4,3x8,5d-7/220  5 72,7 % 66,7 % 58,8 %  
T2 8 FDH-8-L/P-W4,3x8,5d-7/320  7,8 76,5 % 70,9 % 65,0 %  
T2 11 FDH-11-L/P-W4,3x8,5d-7/420  10,8 81,8 % 77,1 % 72,0 %  
T2 13 FDH-13-L/P-W4,3x8,5d-7/520  13,3 84,7 % 80,6 % 76,0 %  
T2 21 FDH-21-L/P-W4,3x8,5d-7/  21 88,9 % 85,7 % 79,2 %  
T2 23 FDH-23-L/P-W4,3x8,5d-7/  23 89,8 % 86,8 % 80,7 %  
T5-E 14 FDH-14-G5-L/P-16/550  13,7 84,7 % 80,6 % 72,1 %  
T5-E 21 FDH-21-G5-L/P-16/850  20,7 89,3 % 86,3 % 79,6 %  
T5-E 24 FDH-24-G5-L/P-16/550  22,5 89,6 % 86,5 % 80,4 %  
T5-E 28 FDH-28-G5-L/P-16/1150  27,8 89,8 % 86,9 % 81,8 %  
T5-E 35 FDH-35-G5-L/P-16/1450  34,7 91,5 % 89,0 % 82,6 %  
T5-E 39 FDH-39-G5-L/P-16/850  38 91,0 % 88,4 % 82,6 %  
T5-E 49 FDH-49-G5-L/P-16/1450  49,3 91,6 % 89,2 % 84,6 %  
T5-E 54 FDH-54-G5-L/P-16/1150  53,8 92,0 % 89,7 % 85,4 %  
T5-E 80 FDH-80-G5-L/P-16/1150  80 93,0 % 90,9 % 87,0 %  
T5-E 95 FDH-95-G5-L/P-16/1150  95 92,7 % 90,5 % 84,1 %  
T5-E 120 FDH-120-G5-L/P-16/1450  120 92,5 % 90,2 % 84,5 %  
T5-C 22 FSCH-22-L/P-2GX13-16/225  22,3 88,1 % 84,8 % 78,8 %  
T5-C 40 FSCH-40-L/P-2GX13-16/300  39,9 91,4 % 88,9 % 83,3 %  
T5-C 55 FSCH-55-L/P-2GX13-16/300  55 92,4 % 90,2 % 84,6 %  
T5-C 60 FSCH-60-L/P-2GX13-16/375  60 93,0 % 90,9 % 85,7 %  
TC-LE 40 FSDH-40-L/P-2G11  40 91,4 % 88,9 % 83,3 %  
TC-LE 55 FSDH-55-L/P-2G11  55 92,4 % 90,2 % 84,6 %  
TC-LE 80 FSDH-80-L/P-2G11  80 93,0 % 90,9 % 87,0 %  
TC-TE 32 FSMH-32-L/P-2GX24q=3  32 91,4 % 88,9 % 82,1 %  
TC-TE 42 FSMH-42-L/P-2GX24q=4  43 93,5 % 91,5 % 86,0 %  
TC-TE 57 FSM6H-57-L/P-2GX24q=5FSM8H-57-L/P-2GX24q=5  56 91,4 % 88,9 % 83,6 %  
TC-TE 70 FSM6H-70-L/P-2GX24q=6FSM8H-70-L/P-2GX24q=6  70 93,0 % 90,9 % 85,4 %  
TC-TE 60 FSM6H-60-L/P-2G8=1  63 92,3 % 90,0 % 84,0 %  
TC-TE 62 FSM8H-62-L/P-2G8=2  62 92,2 % 89,9 % 83,8 %  
TC-TE 82 FSM8H-82-L/P-2G8=2  82 92,4 % 90,1 % 83,7 %  
TC-TE 85 FSM6H-85-L/P-2G8=1  87 92,8 % 90,6 % 84,5 %  
TC-TE 120 FSM6H-120-L/P-2G8=1FSM8H-120-L/P-2G8=1  122 92,6 % 90,4 % 84,7 %  
TC-DD 55 FSSH-55-L/P-GRY10q3  55 92,4 % 90,2 % 84,6 %  '
4.. The following paragraph is added after the first paragraph of Annex IV:
'Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.'