Article 1 
The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘reaction-to-fire’ without need for further testing are set out in the Annex.
Article 2 
The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.
Article 3 
Products shall be considered in relation to their end-use application, where relevant.
Article 4 
This Decision is addressed to the Member States.
Done at Brussels, 9 February 2010.
For the Commission
Günter VERHEUGEN
Vice-President
ANNEX
The table set out in this Annex lists construction products and/or materials which satisfy all the requirements for the performance characteristic ‘reaction-to-fire’ without need for testing.

Product Product details for the jointing system Maximum organic content(% in weight) Class
Air drying jointing compounds for gypsum plasterboards used together with paper jointing tape. Paste ready to use or powder to be mixed with water, on any substrate of at least class A2-s1,d0 with thickness at least 6 mm and with density at least 700 kg/m3 (excluding floorings). Air drying jointing compounds of types 1A, 2A and 3A and paper jointing tape according to EN 13963 7,0 A2-s1,d0