Article 1 
The products and families of products set out in Annex I shall have their conformity attested by a procedure whereby the manufacturer has under its sole responsibility a factory-production control system ensuring that the product is in conformity with the relevant technical specifications.
Article 2 
The products set out in Annex II shall have their conformity attested by a procedure whereby, in addition to a factory-production control system operated by the manufacturer, an approved certification body is involved in assessment and surveillance of the production control or of the product itself.
Article 3 
The procedure for attesting conformity as set out in Annex III shall be indicated in mandates for harmonised standards.
Article 4 
This Decision is addressed to the Member States.
ANNEX I

Doors and gates (with or without related hardware):

— for internal communication only,
— for declared specific uses and/or uses subject to specific requirements, in particular noise, energy, tightness and safety-in-use, other than those mentioned in Annex II to this Decision.
Windows (with or without related hardware):

— for uses other than those specified in Annex II to this Decision.
Shutters and blinds (with or without related hardware):

— for external use.

ANNEX II

Doors and gates (with or without related hardware):

— for use in fire/smoke compartmentation and on escape routes.
Windows (with or without related hardware):

— for use in fire/smoke compartmentation and on escape routes.
Building hardware related to doors and gates:

— for use in fire/smoke compartmentation and on escape routes.

ANNEX III
1. 
For the product(s) and intended use(s) listed below, CEN/Cenelec are requested to specify the following system(s) of attestation of conformity in the relevant harmonised standard(s):


Product(s) Intended use(s) Level(s) or class(es) Attestation of conformity system(s)
Doors and gates (with or without related hardware) fire/smoke compartmentation and on escape routes — 1
other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes) — 3
for internal communication only — 4
Windows (with or without related hardware) fire/smoke compartmentation and on escape routes — 1
any other — 3
Building hardware related to doors, gates and windows fire/smoke compartmentation and on escape routes — 1
any other — 3
Shutters and blinds (with or without related hardware) external use — 4
System 1:See point (i) of Section 2 of Annex III to Directive 89/106/EEC, without audit-testing of samples.
System 3:See point (ii) of Section 2 of Annex III to Directive 89/106/EEC, second possibility.
System 4:See point (ii) of Section 2 of Annex III to Directive 89/106/EEC, third possibility.

The specification for the system should be such that it can be implemented even where the performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirements at all for such characteristic (see Article 2(1) of Directive 89/106/EEC and, where applicable, point 1.2.3 of the Interpretative Documents). In those cases, the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.