Article 1 
Annex II to Directive 2008/98/EC is amended as set out in the Annex.
Article 2 

1. Member States shall bring into force the laws, regulations and administrative provisions necessary to comply with this Directive by 31 July 2016, at the latest. They shall forthwith communicate to the Commission the text of those provisions.When Member States adopt those provisions, they shall contain a reference to this Directive or be accompanied by such a reference on the occasion of their official publication. Member States shall determine how such reference is to be made.
2. Member States shall communicate to the Commission the text of the main provisions of national law which they adopt in the field covered by this Directive.
Article 3 
This Directive shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
Article 4 
This Directive is addressed to the Member States.
Done at Brussels, 10 July 2015.
For the Commission
The President
Jean-Claude JUNCKER
ANNEX

In Annex II to Directive 2008/98/EC, the following text is added under footnote (*):
'The energy efficiency formula value will be multiplied by a climate correction factor (CCF) as shown below:
1.. CCF for installations in operation and permitted in accordance with applicable Union legislation before 1 September 2015.
CCF = 1 if HDD >= 3 350
CCF = 1,25 if HDD <= 2 150
CCF = – (0,25/1 200) × HDD + 1,698 when 2 150 < HDD < 3 350
2.. CCF for installations permitted after 31 August 2015 and for installations under 1 after 31 December 2029:
CCF = 1 if HDD >= 3 350
CCF = 1,12 if HDD <= 2 150
CCF = – (0,12/1 200) × HDD + 1,335 when 2 150 < HDD < 3 350(The resulting value of CCF will be rounded at three decimal places).The value of HDD (Heating Degree Days) should be taken as the average of annual HDD values for the incineration facility location, calculated for a period of 20 consecutive years before the year for which CCF is calculated. For the calculation of the value of HDD the following method established by Eurostat should be applied: HDD is equal to (18 °C — Tm) × d if Tm is lower than or equal to 15 °C (heating threshold) and is nil if Tm is greater than 15 °C; where Tm is the mean (Tmin + Tmax/2) outdoor temperature over a period of d days. Calculations are to be executed on a daily basis (d = 1), added up to a year.'