Article 1 
Decision 2009/11/EC is amended as follows:

((1)) Article 1 is replaced by the following:
'
Article 1 
The use of the following methods is authorised for grading pig carcasses pursuant to point 1 of Section B.IV of Annex V to Council Regulation (EC) No 1234/2007 in Spain:

((a)) the “Fat-O-Meat’er (FOM)” apparatus and the assessment methods related thereto, details of which are given in Part 1 of the Annex;
((b)) the “Fully automatic ultrasonic carcase grading (Autofom)” apparatus and the assessment methods related thereto, details of which are given in Part 2 of the Annex;
((c)) the “Ultrafom 300” apparatus and the assessment methods related thereto, details of which are given in Part 3 of the Annex;
((d)) the “Automatic vision system (VCS2000)” apparatus and the assessment methods related thereto, details of which are given in Part 4 of the Annex;
((e)) the “Fat-O-Meat’er II (FOM II)” apparatus and the assessment methods related thereto, details of which are given in Part 5 of the Annex;
((f)) the “AutoFOM III” apparatus and the assessment methods related thereto, details of which are given in Part 6 of the Annex;
((g)) the “manual method (ZP)” with a ruler and the assessment methods related thereto, details of which are given in Part 7 of the Annex.
The manual method ZP with a ruler, referred to in point (g) of the first paragraph, shall only be authorised for abattoirs:

((a)) where the number of slaughters does not exceed 500 pigs per week on yearly average basis; and
((b)) having a slaughter line with a capacity to process no more than 40 pigs per hour.';
((2)) the Annex is amended in accordance with the Annex to this Decision.
Article 2 
This Decision is addressed to the Kingdom of Spain.
Done at Brussels, 12 July 2012.
For the Commission
Dacian CIOLOȘ
Member of the Commission
ANNEX

In the Annex to Decision 2009/11/EC the following Parts 5, 6 and 7 are added:
'
Part 5  1. The rules provided for in this Part shall apply when the grading of pig carcasses is carried out by means of the apparatus known as “Fat-O-Meat’er (FOM II)”.
 2. The apparatus is a new version of the Fat-O-Meat’er measurement system. The FOM II consists of an optical probe with a knife, a depth measurement device having an operating distance of between 0 and 125 millimetres and a data acquisition and analysis board — Carometec Touch Panel i15 computer (Ingress Protection IP69K). The results of the measurements are converted into estimated lean meat content by the FOM II apparatus itself.
 3. 
Ŷ = 64,53 – 0,876 × X1 + 0,181 × X2

where:

Ŷthe estimated percentage of lean meat in a carcass,X1the thickness of back-fat (including rind) in millimetres, measured perpendicularly to the back of the carcass at 6 cm of the split line, between the third and fourth last ribs,X2the thickness of the dorsal muscle in millimetres, measured at the same time, in the same place and in the same way as X1.

This formula shall be valid for carcasses weighing between 60 and 120 kilograms (warm weight).

Part 6  1. The rules provided for in this Part shall apply when the grading of pig carcasses is carried out by means of the apparatus known as “AutoFOM III”.
 2. The apparatus shall be equipped with sixteen 2 MHz ultrasonic transducers (Carometec A/S), with an operating distance between transducers of 25 mm. The ultrasonic data shall comprise measurements of back fat thickness, muscle thickness and related parameters. The results of the measurements are converted into estimates of the percentage of lean meat by using a computer.
 3. 
Ŷ = 68,44293415 – (0,35254288 × R2P10) – (0,31514342 × R2P15) – (0,19383319 × R2P16) + (0,02067879 × R3P3) + (0,03303812 × R3P5) + (0,02479771 × R3P6) + (0,02710736 × R3P7) + (0,02310621 × R3P9) – (0,07075210 × R4P10)

where:

Ŷthe estimated percentage of lean meat in a carcass,

R2P10, R2P15, R2P16,R3P3, R3P5, R3P6, R3P7, R3P9 and R4P10 are the variables measured by AutoFOM III,
 4. 
This formula is valid for carcasses weighing between 60 and 120 kg (warm weight).

Part 7  1. The rules provided for in this Part shall apply when the grading of pig carcasses is carried out by use of the “manual method (ZP)” measuring by ruler.
 2. This method may be implemented using a ruler, with the grading determined on the basis of the prediction equation. It is based on the manual measurement on the midline of the split carcass of the thickness of the fat and of the thickness of the muscle.
 3. 
Ŷ = 59,89 – 0,821 × F + 0,157 × M

where:

Ŷthe estimated percentage of lean meat in the carcass,Fthe minimum thickness of visible fat (including rind), in millimetres, on the midline of the split carcass in millimetres, covering the M. gluteus medius,Mthe visible thickness of the lumbar muscle, in millimetres, on the midline of the split carcass, measured as the shortest connection between the front (cranial) end of the M. gluteus medius and the upper (dorsal) edge of the vertebral canal.

This formula shall valid for carcasses weighing between 60 and 120 kg (warm weight).
'