Article 1 
The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘reaction to fire’ without need for further testing are set out in the Annex.
Article 2 
The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.
Article 3 
Products shall be considered in relation to their end-use application, where relevant.
Article 4 
This Decision is addressed to the Member States.
Done at Brussels, 6 March 2006.
For the Commission
Günter VERHEUGEN
Vice-President
ANNEX
The tables set out in this Annex, list construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction to fire without need for testing.

Material, Product detail Minimum mean density(kg/m3) Minimum overall thickness(mm) End-use condition Class for floorings
Wood flooring and parquet Solid flooring of oak or beech with surface coating Beech: 680Oak: 650 8 Glued to substrate Cfl - s1
Solid flooring of oak, beech or spruce and with surface coating Beech: 680Oak: 650Spruce: 450 20 With or without air gap underneath
Solid wood flooring with surface coating and not specified above 390 8 Without air gap underneath Dfl - s1
20 With or without air gap underneath
Wood parquet Multilayer parquet with a top layer of oak of at least 5 mm thickness and with surface coating 650(top layer) 10 Glued to substrate Cfl - s1
14 With or without air gap underneath
Multilayer parquet with surface coating and not specified above 500 8 Glued to substrate Dfl - s1
10 Without air gap underneath
14 With or without air gap underneath
Veneered floor covering Veneered floor covering with surface coating 800 6 Without air gap underneath Dfl - s1







Material Product detail Minimum mean density(kg/m3) Minimum thicknesses, total/minimum(mm) End-use condition Class
Panelling and cladding Wood pieces with or without tongue and groove and with or without profiled surface 390 9/6 Without air gap or with closed air gap behind D - s2, d2
12/8 D - s2, d0
Panelling and cladding Wood pieces with or without tongue and groove and with or without profiled surface 390 9/6 With open air gap ≤ 20 mm behind D - s2, d0
18/12 Without air gap or with open air gap behind
Wood ribbon elements Wood pieces mounted on a support frame 390 18 Surrounded by open air on all sides D - s2, d0











Figure a
Figure b