1 

(1) This Order may be cited as the Restrictive Trade Practices (Standards and Arrangements) (Services) Order 1995 and shall come into force on 29th December 1995.
(2) In this Order—
 “the 1976 Act” means the Restrictive Trade Practices Act 1976;
 “arrangements” means, in respect of making available, supplying or obtaining any designated services within the meaning of the 1976 Act, arrangements as to the provision of information or advice to persons to or by whom designated services are supplied or agreed to be supplied;
 “standards” means, in respect of making available, supplying or obtaining any designated services within the meaning of the 1976 Act, standards of performance in the provision of the services or standards of dimension, design, quality or performance in respect of goods used in providing them.
2 

(1) The standards specified in Part I of the Schedule to this Order, being standards adopted by Electricity Association Services Limited on 31st October 1995, are hereby approved for the purposes of section 18(5) of the 1976 Act.
(2) The arrangements specified in Part II of the Schedule to this Order, being arrangements adopted by Electricity Association Services Limited on 31st October 1995, are hereby approved for the purposes of section 18(5) of the 1976 Act.
John M. Taylor
Parliamentary Under Secretary of State for Competition and Consumer Affairs,Department of Trade and Industry
4th December 1995
SCHEDULE
Article 2
PART 1
09–2 The installation of 33kV and higher voltage power cables and associated auxiliary cables
 Amendment 1, 1995 to Issue 3, 1983
09–4 66kV and 132kV impregnated paper insulated oil-filled and gas-pressure type power cable systems
 Amendment 1, 1995 to Issue 3, 1991
09–6 Auxiliary multicore and multipair cables
 Amendment 1, 1995 to Issue 6, 1988
09–7 PVC insulated concentric service cables with stranded copper or solid aluminium phase conductors and copper concentric conductors
 Amendment 1, 1995 to Issue 4, 1981
09–9 Polymeric insulated, combined neutral/earth (CNE) cables with solid aluminium phase conductors and concentric aluminium wire waveform neutral/earth conductor
 Amendment 1, 1995 to Issue 5, 1981
09–11 Heat shrinkable insulating materials for use with 600/1000V cables and accessories
 Amendment 1, 1995 to Issue 1, 1975
09–12 Impregnated paper insulated corrugated aluminium sheathed 6,350/11,000 volt cable
 Amendment 1, 1995 to Issue 2, 1990
09–17 Single core cables for use in substations having extruded insulation and rated voltages of 6,350/11,000 volts and 19,000/33,000 volts
 Amendment 1, 1995 to Issue 2, 1991
26–3 Hand held insulated tools for live working up to 1,000 volts
 Amendment 1, 1995 to Issue 2, 1984
41–10 Switchgear for use on 66 and 132kV distribution systems
 Issue 4, 1995
41–18 Partial discharge testing of bushings, capacitors, instrument transformers and switchgear of rated voltage 7.2–420kV inclusive
 Issue 2, 1995
41–26 Distribution switchgear for servcie up to 36kV (cable connected)
 Amendment 2, 1995 to Issue 1, 1991
41–27 Outdoor distribution switchgear for service up to 36kV (overhead conductor connected)
 Amendment 2, 1995 to Issue 1, 1991
43–91 Stay strands and stay fittings for overhead lines
 Amendment 1, 1995 to Issue 4, 1984
43–96 Fasteners and washers for wood pole overhead lines
 Amendment 1, 1995 to Issue 2, 1986
43–103 Low voltage overhead line temporary shrouding materials
 Issue 1, 1995
C55/4 Insulated sheath power cable systems 1989
 Amendment 1, 1995
C64 Testing procedure for approval of joints for cables generally to BEBS C5 1969
 Amendment 4, 1995
C79 Type approval tests for connectors and terminations for aluminium conductors of insulated power cables 1972
 Amendment 3, 1995
C92 Performances specification for pole top terminations on 6,350/11,000 Volt paper insulated cables 1987
 Part 1: Non-metallic pole boxes for mass-impregnated non-draining (MIND) solid type cables
 Amendment 1, 1995
G12/3 Requirements for the application of protective multiple earthing to low voltage networks 1995
G58/2 Purchase, use, storage, inspection and maintenance of hand held insulated tools for live working up to 1,000 volts 1995
G59/1 Recommendations for the connection of embedded generating plant to the Regional Electricity Companies' distribution systems 1991
 Amendment 2, 1995
L9/3 Structural testing of wood poles prior to climbing or use as a personal support 1995
S15 Standard Schematic Diagrams
 Part 1: Schematic Diagrams 1956
 Amendment 1, 1995
 Part 2: Alarm Schemes 1963
 Amendment 1, 1995
 Part 3: Basic diagrams for voltage and current transformer secondary circuits 1967
 Amendment 3, 1995
ETR 113 Notes of guidance for the protection of embedded generating plant up to 5 MW for operation in parallel with Public Electricity Suppliers' distribution systems
 Revision 1, 1995
SMCC 004 Notes of guidance on the safe working of third parties in close proximity to live low voltage overhead conductors 1995
SMCC 006 Notes of guidance on earthwire replacement with one circuit live on 132kV double circuit power lines 1995
PART II
SMCC 004 Notes of guidance on the safe working of third parties in close proximity to live low voltage overhead conductors 1995
SMCC 006 Notes of guidance on earthwire replacement with one circuit live on 132kV double circuit power lines 1995