1 

(1) This Order may be cited as the Restrictive Trade Practices (Standards and Arrangements) (Services) Order 1993 and shall come into force on 1st November 1993.
(2) In this Order–
 “the 1976 Act” means the Restrictive Trade Practices Act 1976;
 “arrangement” means, in respect of making available, supplying or obtaining any designated services within the meaning of the 1976 Act, an arrangement as to the provision of information or advice to persons to or by whom designated services are supplied or agreed to be supplied;
 “standards” means, in respect of making available, supplying or obtaining any designated services within the meaning of the 1976 Act, standards of performance in the provision of the services or standards of dimension, design, quality or performance in respect of goods used in providing them.
2 

(1) The standards specified in Part I of the Schedule to this Order, being standards adopted by Electricity Association Services Limited on 8th October 1993, are hereby approved for the purposes of section 18(5) of the 1976 Act.
(2) The arrangement specified in Part II of the Schedule to this Order, being an arrangement adopted by Electricity Association Services Limited on 8th October 1993, is hereby approved for the purposes of section 18(5) of the 1976 Act.
Neil Hamilton
Parliamentary Under Secretary of State
Department of Trade and Industry
10th October 1993
SCHEDULE
Article 2
PART I
09—1 Lead sleeves for electric cables (metric units)Amendment 1, 1993 to Issue 1, 1970
09—3 33kV impregnated paper insulated oil–filled and gas pressure type power cable systemsAmendment 1, 1993 to Issue 2, 1982
09—5 275 and 400kV impregnated paper insulated oil–filled and gas compression type power cable systemsAmendment 1, 1993 to Issue 3, 1991
09—10 Porcelain insulators for 33, 66, 132, 275 and 400kV pressure–assisted cable outdoor sealing endsAmendment 1, 1993 to Issue 3, 1976
09—13 Performance specification for high voltage heat–shrinkable components for use with high voltage solid type cables up to and including 33 000 voltsAmendment 1, 1993 to Issue 1, 1981
09—16 Testing specification for metallic sheathed power cables with extruded cross–linked polyethylene insulation and accessories for system voltages of 66kV and 132kVAmendment 1, 1993 to Issue 1, 1983
09—20 Single core cables having cross linked polyethylene insulation and lead sheath for rated voltage 19 000/33 000 volts (Um03736 000 volts)Amendment 1, 1993 to Issue 1, 1990
12—3 Outdoor meter cupboardsIssue 3, 1992
12—9 Wiping glands for metallic–sheathed cablesAmendment 1, 1993 to Issue 2, 1980
12—11 Indoor and outdoor cable boxes for switchgear (for service at system nominal voltages of 6.6,11 and 33kV)Amendment 1, 1993 to Issue 2, 1981
12—12 Compounds for use in 33kV solid type cable accessoriesAmendment 1, 1993 to Issue 1, 1977
12—14 Impregnated crepe paper for cable jointing in solid type cable accessoriesAmendment 1, 1993 to Issue 1, 1976
12—18 Polyester resin/glass fibre protection boxes and protective shrouds for oil–filled and gas–pressure cable accessoriesAmendment 1, 1993 to Issue 1, 1980
12—24 Plastic ducts for buried electric cablesAmendment 1, 1991 and Amendment 2, 1993 to Issue 1, 1989
35—1 Distribution transformers (from 16kVA to 1000kVA)Amendment 1, 1993 to Issue 4, 1985
35—2 Emergency rated system transformers—33/11.5kV delta/star and star/star connectedAmendment 1, 1993 to Issue 4, 1982
35—16 Interface arrangement for direct connection of gas–insulated metal–enclosed switch– gear to 132kV, 275kV and 400kV transformersIssue 1, 1992
37—2 LV distribution fuse–boardsAmendment 1, 1993 to Issue 3, 1990
41—11 Tubular aluminium busbars, connections and terminal fittings for 132kV outdoor substationsAmendment 1, 1993 to Issue 2, 1982
41—24 Guidelines for the design, installation, testing and maintenance of main earthing systems in substationsIssue 1, 1992
41—26 Distribution switchgear for service up to 36kV (cable connected)Amendment 1, 1993 to Issue 1, 1991
41—27 Outdoor distribution switchgear for service up to 36kV (overhead conductor connected)Corrigendum 1992 and Amendment 1, 1993 to Issue 1, 1991
43—1 Survey and preparation of ground line profiles and plotting of tower positions for steel tower overhead transmission lines at 132kV and higher voltagesAmendment 1, 1993 to Issue 2, 1986
43—4 Design of foundations for steel towers for overhead transmission lines at 132kV and higher voltagesAmendment 1, 1993 to Issue 2, 1986
43—5 Fabrication and galvanising of tower and foundation steelwork for overhead transmission lines at 132kV and higher voltagesAmendment 1, 1993 to Issue 2, 1986
43—7 132kV steel tower transmission lines: specification L4(M) — 1978 1 039 175 mm2 ACSR per phase 1 039 70 mm2 ACSR earthwireAmendment 1, 1993 to Issue 2, 1985
43—9 132kV steel tower transmission lines: specification L7(C) — 1978 2 039 175 mm2 ACSR per phase — 1 039 175 mm2 ACSR earthwireErratum 1991 to Amendment 1, 1993 to Issue 1, 1986
43—12 Insulated aerial bundled conductors erection requirements for lv overhead distribution systemsAmendment 1, 1993 to Issue 1, 1986
43—14 Conductor fitting and associated apparatus for use with lv aerial bundled conductorsErratum 1991 to Amendment 1, 1993 to Issue 2, 1990
43—30 Low voltage overhead lines on wood polesAmendment 1, 1993 to Issue 2, 1981
43—40 High voltage single circuit overhead lines on wood polesAmendment 1, 1993 to Issue 1, 1988
43—50 132kV single circuit overhead lines on wood polesAmendment 1, 1993 to Issue 1, 1984
43—88 Selection and treatment of wood poles and associated timber for overhead linesPart 1: Technical requirementsIssue 4, 1993Part 2: Essential quality requirementsIssue 1, 1992
43—90 Anti–climbing devices and safety signs for hv lines up to and including 400kVIssue 4, 1993
43—92 Conductor fittings for overhead linesAmendment 1, 1993 to Issue 2, 1985
43—93 Line insulatorsAmendment 2, 1993 to Issue 3, 1986
43—95 Steelwork for overhead linesAmendment 1, 1993 to Issue 5, 1989
48—2 Fault passage indicators for 6.6kV and 11kV underground and overhead distribution systemsAmendment 1, 1993 to Issue 1, 1974
48—3 Instantaneous high–impedance differential protectionAmendment 2, 1993 to Issue 1, 1977
48—4 DC relays associated with a tripping function in protection systemsAmendment 1, 1993 to Issue 3, 1983
50—2 Bimetallic ammetersAmendment 1, 1993 to Issue 1, 1975
T2 Specification for transformers and reactors1966Section 26: Tap–changing equipmentRevision 1, 1991
C84—1 Operation of oil–filled pressure–assisted cable systems up to 400kV operating voltage1992
C90 Type approval tests for straight joints for 6350/11 000 volts three–core mass impregnated non–draining paper insulated solid type cables1984Amendment 1, 1993
C93 Type approval tests for mechanical connections to metallic sheaths of cables1989Addendum, 1992
C94 Guide for physical inspection of newly manufactured 33kV mind cables1991
G39/1 Model code of practice covering electrical safety in the planning, installation, commissioning and maintenance of public lighting and other street furniture1992
G59/1 Recommendations for the connection of embedded generating plant to the Regional Electricity Companies' distribution systems1991Amendment 1, 1992
G74 Procedure to meet the requirements of IEC 909 for the calculation of short–circuit currents in three–phase AC power systems1992
ETR119 Third report on optical fibres1991Appendices
PART II
G74 Procedure to meet the requirements of IEC 909 for the calculation of short–circuit currents in three–phase AC power systems1992